Grade 4

Trikdis E16 Ethernet Communicator - IP module

    Made in EU
  • Brand: Trikdis
  • Product Code: E16
  • Availability: In Stock
  • 33,536Ft Ex Tax: 27,946Ft


Available Options


E16 with Honeywell vista. Ethernet communicator setup with Protegus app.

Trikdis E16 Ethernet Smart Communicator directly connects to supported DSC, Paradox, UTC Interlogix (CADDX), Innerrange, Texecom, Honeywell, Crow and Pyronix alarm control panels.

Communicator also works with Protegus 2 Android / Iphone and web app. With Protegus 2 users can control their alarm system and appliances remotely and get notifications about security system events. Protegus 2 app is compatible with all security alarm panels from various manufacturers that are supported by the E16 communicator. Communicator can transmit event notifications to the Central Monitoring Station and work with Protegus 2 simultaneously.

Communicator transmits full event information to the Central Monitoring Station.

paradox logodsc logo

The Trikdis E16 * and E16T communicators are excellent replacement for the Paradox IP150+ IP module and DSC ENVISA LINK4 Ethernet communicator.

What does Trikdis offer?

  • Reliable operation
  • Free Android, Iphone and web application
  • * Connects directly to the control panel - this is a unique feature that nobody else is capable of
  • Remote control (arming / disarming)

Data Bus or serial port connectable and Direct Controllable Security Control panels

Direct controllable models are marked red.

PARADOX
Spectra SP4000, SP5500, SP5500+*, SP6000, SP6000+*, SP7000, SP7000+*, SP65, 1727, 1728, 1738
Magellan MG5000, MG5050, MG5050E, MG5075, MG5050+*,
DIGIPLEX EVO48, NE96, EVO96, EVO192*, EVOHD* (*Fw. 7.50 or higher)
ESPRIT E55, 728ULT, 738ULT
* the serial port of the marked NEW control panels has been locked by the factory. The serial port must be unlocked before it can communicate with any external device. How to unlock Serial Port
DSC
PC585, PC1565, PC1616, PC1832, PC1864, PC1404, PC5015, PC5020
Interlogix
NetworX (Caddx) NX-4v2, NX-6v2, NX-8v2, NX-8e
Texecom
Premier 24, 48, 88, 168, 412, 816, 832, 832+
Premier Elite 12, 24, 48, 64, 88, 168
Innerrange
Inception, Integriti
Honeywell
Ademco Vista-15, Ademco Vista-20, Ademco Vista-48
Crow
Runner 4/8, 8/16
E16T

You don't see your model listed above?

For not supported and other manufacturers control panels, use the E16T communicator with telephone line (TIP RING) connection.

Main features:

  • Ethernet, IP-based communicator compatible with the popular security control panels from major manufacturers
  • Uniquely this communicator is wired to the control panels data bus or serial port instead of , it is not a TIP RING, which results faster communication
  • When Protegus 2 service is enabled, events are first delivered to CMS, and only then are sent to app users.
  • No fixed IP nor dynamic DNS is required, the messages are transmitted by the Protegus 2 server securely

    Notifies users:

    • Users are notified about events and can control the system via the free Protegus 2 Android / Iphone and web app
    • Push” and special sound notifications informing about events.
    • Remote system Arm/Disarm.

    Controllable outputs:

    • 3 double I/O terminals that can be set either as input (IN) or controllable output (OUT) terminals.
    • Outputs controlled by the Protegus 2 app.
    • Add additional inputs and controllable outputs with iO expanders via RS485 port
    • Remote control of connected devices (lights, gates, ventilation systems, heating, sprinklers, etc.).

    Quick setup:

    • Settings can be saved to file and quickly written to other communicators.
    • Two access levels for configuring the device for CMS administrator and for the installer.
    • Quick and easy configuration and firmware updates via USB or remotely after initial setup with Trikdis programming software.

    Central monitoring station:

    • Sends events to TRIKDIS software or hardware receivers that work with any monitoring software.
    • Can send event messages to universal SIA DC-09 and SUR-GUARD TL150 receivers
    • The module transmits the messages of the control panel to the monitoring station in Contact ID code format
    • Connection supervision by polling to IP receiver every 30 seconds (or by user-defined period).
    • Backup channel, that will be used if connection with the primary channel is lost.
    • With parallel communication channels events can be sent to two receivers at the same time.

      Wiring to control panel

      paradox logo

      If you want to connect E16 to a Paradox control panel you will need a Trikdis CRP2 SERIAL cable.

      texecom logo

      If you want to connect E16 to a Texecom control panel you will need a Trikdis CRP4 SERIAL cable.

      What does Data Bus or Serial port connection mean?

      The communicator understands the inner language of the control panel (one-way communicaton). Like keypads or other peripherals, the communicator also sees the events sent by the control panel and transmits them according to the settings.

      For more info please check out our article.

      Direct control

      Direct Control offers even more. The communicator not only receives the notifications from the control panel, but also some of the functions on the keypad is available (two-way communication).

      These are

      • Arming / disarming the system or a partitions using the user keypad code
      • Sensing the status of zones
      • Zone bypass
      • Automatic partition and zone mapping

      Communication

      Transmission Channel
      Ethernet / LAN / IP communication IEEE802.3, 10 Base-T, port RJ45
      Network configuration
      DHCP or Manual
      Connection with alarm control panel
      Data bus or Serial port (depends from brand)
      Event reporting transmission channels
      To main and backup receivers of up to 2 different security companies
      To Protegus cloud, to iOS/Android Protegus mobile apps
      Report transmission directions
      2G (GPRS) or 4G
      WiFi, LAN (with optional E485 module)
      SMS or voice call
      VHF / UHF radio signaling (with optional T16 communicator)
      Transmission to remote monitoring
      TCP / IP, UDP / IP
      Transmission Protocol, Encryption
      TRK, DC-09_2007, DC-09_2012, TL150
      Event Transmission
      Contact ID code
      Event log / number of stored events
      Yes, 100 events
      Send periodic test reports
      Yes
      RS485
      Yes

      Compatible devices

      Supported Modules
      iO-8 Expansion Module - 8 terminal I / O
      iO Expansion Module
      iO-MOD - iO-WL radio transceiver expansion modules
      Max. number of RS485 modules
      max. 8
      RS485 data bus length
      up to 100m

      Inputs

      Dual Function Contacts (Output or Input)
      3
      Inputs
      3
      Input types
      NC, NO, NC / EOL, NO / EOL, NC / DEOL, NO / DEOL
      Loop resistance
      2.2kΩ

      Outputs

      Dual Function Contacts (Output or Input)
      3
      Control
      Mobile app, browser

      Programming

      Programming modes
      USB, IP
      Programming Software
      Yes, windows
      Remote Programming
      Yes

      Users

      Protegus users
      Unlimited
      Mobile Application
      Yes
      Web Application
      Yes
      Push notification
      Yes
      Limit Alerts
      Yes

      Technical data

      Operating environment
      -10°C - +50°C, relative humidity up to 80% + 20°C
      Power supply
      10-18V DC
      Current consumption (nominal)
      100 mA
      Current consumption (max)
      250 mA
      Detachable terminal blocks
      Yes
      Size
      88 x 62 x 26 mm
      Weight
      80g
      PGM output
      0.15A 30 VDC max.